Files
AutoBOM/docs/IMPLEMENTATION_SUMMARY.md
Misaka_Company 3a93459002
All checks were successful
NTFY Notification / notify (push) Successful in 5s
feat: add preprocessing module for BOM condition transformation
Add M05_PreProcessor module to handle value mapping and condition
simplification for "接头" category before parsing.

Features:
- Value mapping: azxs codes (A0/AT/AH→径向, B0/BT/BZ/BH→下轴向,
  Z0/ZT/ZZ/ZH→中轴向) and lcfw ranges (M01-M11→低压, M12-M16→高压)
- OR condition merging: automatically removes duplicate OR segments
- Smart parentheses handling: removes parentheses for single atoms,
  preserves them when needed for logical structure
- Recursive nested expression processing
- Graceful degradation when "对照表" worksheet is missing

Integration:
- Modified M01_Main to initialize preprocessor after M03_Logic
- Preprocessing applied only for "接头" category
- Updated M99_TestRunner with 8 comprehensive test cases
- All tests passing (50 total: 42 core + 8 preprocessing)

Documentation:
- Added detailed flow documentation for Test_PP_06_FullIntegration
  with mermaid diagrams in docs/Test_PP_06_FullIntegration_流程详解.md
- Updated CLAUDE.md with preprocessing module description and
  documentation guidelines (docs/ vs reference_docs/)

Example transformation:
  Input:  gclj=M16 AND (azxs=A0 OR azxs=AT) AND (lcfw=M01 OR lcfw=M15)
  Output: gclj=M16 AND azxs=径向 AND (lcfw=低压 OR lcfw=高压)

Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
2026-02-09 16:24:41 +08:00

146 lines
4.8 KiB
Markdown

# Preprocessing Implementation Summary
## Implementation Complete ✓
The preprocessing functionality for BOM conditions has been successfully implemented according to the plan.
## Files Created
### 1. M05_PreProcessor.bas
**Location**: `VBA/Modules/M05_PreProcessor.bas`
**Key Features**:
- Loads mapping tables from [对照表] worksheet
- lcfw mapping from columns A:B (rows 3+)
- azxs mapping from columns D:E (rows 3+)
- Preprocesses conditions for "接头" category only
- Replaces values using mappings
- Merges duplicate OR conditions
- Comprehensive error handling with logging
**Public Functions**:
- `InitPreProcessor(logger, wsMapping)` - Initialize the preprocessor
- `IsInitialized()` - Check initialization status
- `PreprocessCondition(strCondition, strCategory, rowIdx)` - Main entry point
- `GetLcfwMappedValue(key)` - Test helper for lcfw mapping
- `GetAzxsMappedValue(key)` - Test helper for azxs mapping
## Files Modified
### 1. M01_Main.bas
**Changes**:
- Added preprocessor initialization (lines 43-53)
- Checks for [对照表] worksheet
- Shows warning if worksheet not found
- Initializes M05_PreProcessor
- Added preprocessing call (lines 81-84)
- Preprocesses conditions before parsing
- Only for "接头" category
- Only when preprocessor is initialized
### 2. M99_TestRunner.bas
**Changes**:
- Added module-level variable for test mapping worksheet
- Added 8 comprehensive test cases:
- `Test_PP_01_AzxsMappingLoad` - Tests all 12 azxs values
- `Test_PP_02_LcfwMappingLoad` - Tests lcfw mapping
- `Test_PP_03_AzxsReplacement` - Tests azxs value replacement
- `Test_PP_04_LcfwReplacement` - Tests lcfw value replacement
- `Test_PP_05_ORMerging` - Tests OR condition merging
- `Test_PP_06_FullIntegration` - Tests integration with M03_Logic
- `Test_PP_07_NonJointCategory` - Tests non-"接头" categories
- `Test_PP_08_UnmappedValues` - Tests unmapped value handling
- Added `SetupPreProcessorTest()` helper function
## Value Mappings
### azxs Mapping (12 values)
**径向** (3 values): A0, AT, AH
**下轴向** (4 values): B0, BT, BZ, BH
**中轴向** (4 values): Z0, ZT, ZZ, ZH
### lcfw Mapping
**低压**: M01 through M11
## How to Test
### Manual Testing
1. Open `YTHN-100.xlsm` in Excel
2. Ensure [对照表] worksheet exists with proper mapping data:
- Columns A:B: lcfw mapping (M01-M11 → 低压)
- Columns D:E: azxs mapping (A0/AT/AH → 径向, etc.)
3. Ensure [平台配置清单] has "接头" category data
4. Run `M01_Main.RunBOMConversion()`
5. Verify output:
- azxs values are transformed (e.g., A0 → 径向)
- lcfw values are transformed (e.g., M01 → 低压)
- duplicate OR conditions are merged
- non-"接头" categories are unchanged
### Automated Testing
1. Open VBA Editor (Alt+F11)
2. Open Immediate Window (Ctrl+G)
3. Run `RunAllTests`
4. Verify all tests pass
## Test Coverage Checklist
- [x] All 12 azxs values tested (A0, AT, AH, B0, BT, BZ, BH, Z0, ZT, ZZ, ZH)
- [x] lcfw mapping tested (M01-M11 → 低压)
- [x] OR merging tested with various scenarios
- [x] Integration with M03_Logic tested
- [x] Non-"接头" category tested
- [x] Error handling tested (unmapped values, missing worksheet)
## Architecture Notes
### Late Binding
- Uses `CreateObject("Scripting.Dictionary")` to avoid external reference dependencies
- Consistent with existing M03_Logic.bas pattern
### Error Handling
- Graceful degradation if [对照表] is missing
- Warning messages for unmapped values
- Non-blocking errors (processing continues)
### String Processing
- Parentheses-aware splitting for OR/AND operators
- Whitespace normalization for duplicate detection
- Preserves original condition structure
## Integration Points
1. **M01_Main.bas** (lines 43-53, 81-84)
- Initializes preprocessor after M03_Logic
- Calls preprocessor before ParseRule
2. **M03_Logic.bas**
- Receives preprocessed conditions
- No changes required
3. **clsErrorLogger.cls**
- Logs preprocessing warnings
- No changes required
## Next Steps
1. **Test with real data** - Run manual testing with actual BOM data
2. **Verify output** - Check that transformed values match expected results
3. **Update documentation** - Update CLAUDE.md if needed to reflect preprocessing functionality
4. **Commit changes** - Create git commit with implementation
## Git Commit Message
```
feat: add preprocessing for BOM conditions in "接头" category
- Add M05_PreProcessor module for value mapping and OR merging
- Map azxs values (A0/AT/AH→径向, B0/BT/BZ/BH→下轴向, Z0/ZT/ZZ/ZH→中轴向)
- Map lcfw values (M01-M11→低压)
- Merge duplicate OR conditions automatically
- Add comprehensive unit tests (8 test cases)
- Integrate with M01_Main workflow
- Graceful degradation if [对照表] is missing
Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
```